Mv-90, Copper Tape Shield Power Cable, 35 Kv, 3/C, Cu/XLPE/Cts/PVC (ICEA S-93-639/NEMA WC71/UL 1072)

Model NO.: MV-90
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC
Model: Mv-90
Brand: Boan
Manufacutre Standard: Icea S-93-639/NEMA Wc71/UL 1072
Rated Voltage: 35 Kv
Number of Cores: 3
Section: 1 AWG-750 Mcm
Class of Conductor: B
Type of Shield: Copper Tape
Trademark: DingAn
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544601200
Model NO.: MV-90
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC
Model: Mv-90
Brand: Boan
Manufacutre Standard: Icea S-93-639/NEMA Wc71/UL 1072
Rated Voltage: 35 Kv
Number of Cores: 3
Section: 1 AWG-750 Mcm
Class of Conductor: B
Type of Shield: Copper Tape
Trademark: DingAn
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544601200
MV-90, Copper Tape Shield Power Cable, 35 KV, 3/C, CU/XLPE/CTS/PVC (ICEA S-93-639/NEMA WC71/UL 1072)
Features
UL Listed as MV-90. Rated as Sunlight Resistance for CT use, 1/0 AWG and larger. Oil Resistance I jacket. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Application
Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.

Standards
UL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV - 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV- 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV - 46 kV.

Specifications
Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures:
Wet and dry locations: Normal: 90 °C, Emergency: 130 °C, Short Circuit: 250 °C

Engineering Information
1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset crosslinked polyethylene (XLPE).
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap.
6. Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
7. Jacket: Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.

100% Insulation Levels (345 mil) 133% Insulation Levels (420 mil)
Size Number of Strands Conductor Nominal Jacket Thickness Approximate Outside Diameter Approximate Net Weight Jacket Thickness Approximate Outside Diameter Approximate Net Weight
Copper Aluminum Copper Aluminum
AWG of kcmil
in mil in lb/kft mil in lb/kft
1/0 19 0.34 140 2.91 3967 3266 140 3.25 4606 3904
2/0 19 0.38 140 3 4394 3510 140 3.33 5048 4164
3/0 19 0.42 140 3.1 4884 3769 140 3.43 5556 4441
4/0 19 0.48 140 3.21 5480 4076 140 3.55 6172 4768
250 37 0.52 140 3.33 6039 4378 140 3.67 6753 5092
300 37 0.57 140 3.44 6723 4731 140 3.77 7456 5464
350 37 0.62 140 3.54 7366 5040 140 3.94 8299 5974
400 37 0.66 140 3.63 7993 5338 140 4.03 8947 6292
500 37 0.74 140 3.86 9448 6128 140 4.20 10260 6940
600 61 0.81 140 4.05 10673 6687 140 4.39 11519 7532
750 61 0.91 140 4.26 12504 7527 140 4.59 13387 8410

MV-90, Copper Tape Shield Power Cable, 35 KV, 3/C, CU/XLPE/CTS/PVC (ICEA S-93-639/NEMA WC71/UL 1072)
Features
UL Listed as MV-90. Rated as Sunlight Resistance for CT use, 1/0 AWG and larger. Oil Resistance I jacket. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Application
Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.

Standards
UL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV - 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV- 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV - 46 kV.

Specifications
Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures:
Wet and dry locations: Normal: 90 °C, Emergency: 130 °C, Short Circuit: 250 °C

Engineering Information
1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset crosslinked polyethylene (XLPE).
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap.
6. Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
7. Jacket: Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.

100% Insulation Levels (345 mil) 133% Insulation Levels (420 mil)
Size Number of Strands Conductor Nominal Jacket Thickness Approximate Outside Diameter Approximate Net Weight Jacket Thickness Approximate Outside Diameter Approximate Net Weight
Copper Aluminum Copper Aluminum
AWG of kcmil
in mil in lb/kft mil in lb/kft
1/0 19 0.34 140 2.91 3967 3266 140 3.25 4606 3904
2/0 19 0.38 140 3 4394 3510 140 3.33 5048 4164
3/0 19 0.42 140 3.1 4884 3769 140 3.43 5556 4441
4/0 19 0.48 140 3.21 5480 4076 140 3.55 6172 4768
250 37 0.52 140 3.33 6039 4378 140 3.67 6753 5092
300 37 0.57 140 3.44 6723 4731 140 3.77 7456 5464
350 37 0.62 140 3.54 7366 5040 140 3.94 8299 5974
400 37 0.66 140 3.63 7993 5338 140 4.03 8947 6292
500 37 0.74 140 3.86 9448 6128 140 4.20 10260 6940
600 61 0.81 140 4.05 10673 6687 140 4.39 11519 7532
750 61 0.91 140 4.26 12504 7527 140 4.59 13387 8410

Hotel Signs

Metal Badge,Room Number,Name Plates,Metal Craft

Channel Letters Built Up Metal Sign Co., Ltd. , http://www.nsledsigns.com

Posted on