Model NO.: KVV KVVR KVV22 KVVP2 etc.
Material Shape: Round Wire
Range of Application: Fixed Installation, Construction, Industrial, Powe
Certification: ISO9001, CE, CCC
Brand: Gdyg
Warranty: 12 Months
Supply Record: America, Australia, African Countries, Arabian Co
Operating Temperature: 70 Degree or 90 Degree
Manufacture Standard: BS, GB, IEC
Voltage: Low and Medium Voltage Cable
Color: Black or as Request
Current: AC & DC
Sepcial Applicaton: Low Smoke Power Cable
Business Type: Manufacturer
Key Word 1: PVC Power Cable
Trademark: GDYG
Transport Package: Fumigated Steel-Wooden Drum/Wooden Drum
Specification: multicore cable
Origin: Guangdong, China
HS Code: 8544492100
Model NO.: KVV KVVR KVV22 KVVP2 etc.
Material Shape: Round Wire
Range of Application: Fixed Installation, Construction, Industrial, Powe
Certification: ISO9001, CE, CCC
Brand: Gdyg
Warranty: 12 Months
Supply Record: America, Australia, African Countries, Arabian Co
Operating Temperature: 70 Degree or 90 Degree
Manufacture Standard: BS, GB, IEC
Voltage: Low and Medium Voltage Cable
Color: Black or as Request
Current: AC & DC
Sepcial Applicaton: Low Smoke Power Cable
Business Type: Manufacturer
Key Word 1: PVC Power Cable
Trademark: GDYG
Transport Package: Fumigated Steel-Wooden Drum/Wooden Drum
Specification: multicore cable
Origin: Guangdong, China
HS Code: 8544492100
PVC Sheathed Flexible Control Cable, XLPE Insulated Copper Conductor Power Cable
Type and NameÂ
Type | Name |
KVV | Copper conductor PVC insulated PVC sheathed control cable |
KVVP2 | Copper conductor PVC insulated PVC sheathed copper tape screened control cable |
KVV22 | Copper conductor PVC insulated PVC sheathed steel tape armored control cable |
KVVP2-22 | Copper conductor PVC insulated PVC sheathed copper tape screened, steel tape armored control cable |
KVVR | Copper conductor PVC insulated PVC sheathed control flexible cable |
KVV32 | Copper conductor PVC insulated PVC sheathed steel wire armored control cable |
KVVP2-32 | Copper conductor PVC insulated PVC sheathed copper tape screened steel wire armored control cable |
KYJV | Copper conductor XLPE insulated PVC sheathed control cable |
KYJVP2 | Copper conductor XLPE insulated PVC sheathed copper tape screened control cable |
KYJV22 | Copper conductor XLPE insulated PVC sheathed steel tape armored control cable |
KYJVP2-22 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel tape armored control cable |
KYJV32 | Copper conductor XLPE insulated PVC sheathed steel wire armored control cable |
KYJVP2-32 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel wire armored control cable |
Construction SketchÂ
Â
1.Conductor
2.Conductor screen (no light type)
3.Filler
4.Wrapping tape
5.Copper tape screen
6.Sheath
7.Extruded or lapped bedding
8.Double steel tape armour
Standards
It is manufactured in accordance with GB/T9330-2008, and the factory can also manufacture the cables in accordance with other standards such as IEC, BS, DIN, etc.Â
Characteristics and Applications
Plastic insulated control cable are used for connecting electrical equipments. It applies to controlling, monitoring and protective system with A.C. rated voltage U0/U up to and including 450/750V.
The main features of the flame retardant PVC control cable is hard to get fire or that the continuous burning of cables is very limited when it is on fire. It applies to the places with special demands of flame retardant property.Â
Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places necessary to resist fire.Â
Â
Main Technical Parameter4.Wrapping tape
5.Copper tape screen
6.Sheath
7.Extruded or lapped bedding
8.Double steel tape armour
Standards
It is manufactured in accordance with GB/T9330-2008, and the factory can also manufacture the cables in accordance with other standards such as IEC, BS, DIN, etc.Â
Characteristics and Applications
Plastic insulated control cable are used for connecting electrical equipments. It applies to controlling, monitoring and protective system with A.C. rated voltage U0/U up to and including 450/750V.
The main features of the flame retardant PVC control cable is hard to get fire or that the continuous burning of cables is very limited when it is on fire. It applies to the places with special demands of flame retardant property.Â
Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places necessary to resist fire.Â
Â
KVV, ZC-KVV
Number of cores  x Nominal cross-section mm2 |
Kind of  conductor |
Reference  outside diameter  of cable mm |
Reference weight of cable kg/km |
Max.D.C.  resistance  at 20ºC Ω/km |
Min.insulation   resistance    at 70ºC MΩ·km |
2 x 0.75 | 1 | 7.2 | 61 | 24.5 | 0.012 |
2 x 0.75 | 2 | 7.5 | 65 | 24.5 | 0.014 |
2 x 2.5 | 1 | 9.6 | 124 | 7.41 | 0.01 |
2 x 2.5 | 2 | 10.2 | 135 | 7.41 | 0.01 |
2 x 10 | 2 | 15.7 | 377 | 1.83 | 0.0065 |
5 x 0.75 | 1 | 8.7 | 101 | 24.5 | 0.012 |
5 x 0.75 | 2 | 9.1 | 108 | 24.5 | 0.014 |
5 x 2.5 | 1 | 12.7 | 247 | 7.41 | 0.01 |
5 x 2.5 | 2 | 13.4 | 267 | 7.41 | 0.01 |
5 x 10 | 2 | 20.4 | 769 | 1.83 | 0.0065 |
10 x 0.75 | 1 | 11.6 | 176 | 24.5 | 0.012 |
10 x 0.75 | 2 | 12.2 | 189 | 24.5 | 0.014 |
10 x 2.5 | 1 | 17.2 | 447 | 7.41 | 0.01 |
10 x 2.5 | 2 | 18.2 | 483 | 7.41 | 0.01 |
10 x 10 | 2 | 28.4 | 1452 | 1.83 | 0.0065 |
30 x 0.75 | 1 | 17.6 | 450 | 24.5 | 0.012 |
30 x 0.75 | 2 | 18.6 | 483 | 24.5 | 0.014 |
30 x 2.5 | 1 | 26 | 1167 | 7.41 | 0.01 |
30 x 2.5 | 2 | 27.6 | 1262 | 7.41 | 0.01 |
61 x 0.75 | 1 | 23.8 | 857 | 24.5 | 0.012 |
61 x 0.75 | 2 | 25.1 | 906 | 24.5 | 0.014 |
61 x 2.5 | 1 | 36 | 2320 | 7.41 | 0.01 |
61 x 2.5 | 2 | 38.3 | 2509 | 7.41 | 0.01 |
Our company
Established in 1988, Vango Cable is a leading provider in Cable industry. It is located in Qingyuan, Guangdong. we are the main supplier of cable & conductor and special transmission conductor of Natianal Power Grid and China Southern Power Grid. We can manufacture different cables according to the needs of different countries and different standards.
Workshop
Customers
Certificates
PVC Sheathed Flexible Control Cable, XLPE Insulated Copper Conductor Power Cable
Type and NameÂ
Type | Name |
KVV | Copper conductor PVC insulated PVC sheathed control cable |
KVVP2 | Copper conductor PVC insulated PVC sheathed copper tape screened control cable |
KVV22 | Copper conductor PVC insulated PVC sheathed steel tape armored control cable |
KVVP2-22 | Copper conductor PVC insulated PVC sheathed copper tape screened, steel tape armored control cable |
KVVR | Copper conductor PVC insulated PVC sheathed control flexible cable |
KVV32 | Copper conductor PVC insulated PVC sheathed steel wire armored control cable |
KVVP2-32 | Copper conductor PVC insulated PVC sheathed copper tape screened steel wire armored control cable |
KYJV | Copper conductor XLPE insulated PVC sheathed control cable |
KYJVP2 | Copper conductor XLPE insulated PVC sheathed copper tape screened control cable |
KYJV22 | Copper conductor XLPE insulated PVC sheathed steel tape armored control cable |
KYJVP2-22 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel tape armored control cable |
KYJV32 | Copper conductor XLPE insulated PVC sheathed steel wire armored control cable |
KYJVP2-32 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel wire armored control cable |
Construction SketchÂ
Â
1.Conductor
2.Conductor screen (no light type)
3.Filler
4.Wrapping tape
5.Copper tape screen
6.Sheath
7.Extruded or lapped bedding
8.Double steel tape armour
Standards
It is manufactured in accordance with GB/T9330-2008, and the factory can also manufacture the cables in accordance with other standards such as IEC, BS, DIN, etc.Â
Characteristics and Applications
Plastic insulated control cable are used for connecting electrical equipments. It applies to controlling, monitoring and protective system with A.C. rated voltage U0/U up to and including 450/750V.
The main features of the flame retardant PVC control cable is hard to get fire or that the continuous burning of cables is very limited when it is on fire. It applies to the places with special demands of flame retardant property.Â
Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places necessary to resist fire.Â
Â
Main Technical Parameter4.Wrapping tape
5.Copper tape screen
6.Sheath
7.Extruded or lapped bedding
8.Double steel tape armour
Standards
It is manufactured in accordance with GB/T9330-2008, and the factory can also manufacture the cables in accordance with other standards such as IEC, BS, DIN, etc.Â
Characteristics and Applications
Plastic insulated control cable are used for connecting electrical equipments. It applies to controlling, monitoring and protective system with A.C. rated voltage U0/U up to and including 450/750V.
The main features of the flame retardant PVC control cable is hard to get fire or that the continuous burning of cables is very limited when it is on fire. It applies to the places with special demands of flame retardant property.Â
Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places necessary to resist fire.Â
Â
KVV, ZC-KVV
Number of cores  x Nominal cross-section mm2 |
Kind of  conductor |
Reference  outside diameter  of cable mm |
Reference weight of cable kg/km |
Max.D.C.  resistance  at 20ºC Ω/km |
Min.insulation   resistance    at 70ºC MΩ·km |
2 x 0.75 | 1 | 7.2 | 61 | 24.5 | 0.012 |
2 x 0.75 | 2 | 7.5 | 65 | 24.5 | 0.014 |
2 x 2.5 | 1 | 9.6 | 124 | 7.41 | 0.01 |
2 x 2.5 | 2 | 10.2 | 135 | 7.41 | 0.01 |
2 x 10 | 2 | 15.7 | 377 | 1.83 | 0.0065 |